|
Sign In to gain access to subscriptions and/or personal tools.
|
Wear and Marginal Breakdown of Composites with Various Degrees of Cure
J.L. Ferracane
Department of Biomaterials and Biomechanics
J.C. Mitchem
Department of Biomaterials and Biomechanics
J.R. Condon
Department of Biomaterials and Biomechanics
R. Todd
Department of Removable Prosthodontics, Oregon Health Sciences University, 611 S.W. Campus Drive, Portland, Oregon 97201
Loss of anatomical form due to wear has been cited as one factor limiting the clinical use of posterior composites. The physical properties and possibly the wear resistance of composite are influenced by the extent to which it is cured. The aim of this study was to vary degree of conversion (DC) in composites to test the hypothesis that resistance to wear and marginal breakdown could be improved by enhanced curing. A light-cured hybrid composite containing a 50% Bis-GMA/50% TEGDMA resin and 62 vol% of strontium glass (1 to 2 µm) with microfill silica was formulated (Bisco). Composite was placed into two 2.5-mm-diameter cylindrical holes in Co-Cr teeth replacing first and second molars in the mandibular dentures of 50 edentulous patients. The composites were light-cured for different time periods (9 s, 12 s, 25 s, 40 s, and 40 s + 10 min at 120°C) and then polished. The microfill Heliomolar was also tested. DC (%) was measured by FTIR and ranged between 55% for 9 s of light-curing and 67% for 40 s of light-curing followed by heat application. Impressions were evaluated at baseline, 6 mo, 1 yr, and 2 yrs. Stone casts were evaluated independently by three observers to determine the % of the total margin exhibiting breakdown. Epoxy replicas were measured with a profilometer for wear. Wear of the hybrid composite at 2 yrs ranged from a high of 144 µm with 9 s of light-curing to a low of 36 µm with 40 s of light-curing followed by heat. Heliomolar exhibited from 11 to 16 µm of wear at 2 yrs. There was a strong negative correlation (r2 = 0.91) between the degree of cure and the abrasive wear of the hybrid composites. Marginal breakdown was negligible for the hybrids, and was reduced for the microfill from 40% to 15% of the margin by heat treatment. This study showed that the resistance to abrasive wear of a dental composite could be improved by enhancement of its degree of conversion.
Key Words: composite wear marginal fracture degree of cure clinical
REFERENCES
- Bayne SC, Taylor DF, Heymann HO (1992). Protection hypothesis for composite wear. Dent Mater 8:305-309.[Medline]
[Order article via Infotrieve]
- Bryant RW, Hodge KL (1994). A clinical evaluation of posterior composite resin restorations. Austr Dent J 39:77-81.
- Bryant RW, Marzbani N., Hodge KV (1992). Occlusal margin defects around different types of composite resin restorations in posterior teeth. Oper Dent 17:215-221.[Medline]
[Order article via Infotrieve]
- Dietschi D., Holz J. ( 1990). A clinical trial of four light-curing posterior composite resins: two-year report. Quint Int 21:965-975.
- Ferracane JL, Berge HX (1995). Fracture toughness of experimental dental composites aged in ethanol. J Dent Res 74:1418-1423.
- Ferracane JL, Condon JR (1992). Post-cure heat treatments for composites: properties and fractography. Dent Mater 8:290-295.[Medline]
[Order article via Infotrieve]
- Ferracane JL, Marker VA (1992). Solvent degradation and reduced fracture toughness in aged composites. J Dent Res 71:13-19.
- Fukushima M., Setcos JC, Phillips RW (1988). Marginal fracture of posterior composite resins. J Am Dent Assoc 117:577-583.[Abstract]
- Gerbo LR, O'Neal SJ, Leinfelder KF, Wright WW (1992). Two year comparison of indirect versus direct posterior composite restorations (abstract). J Dent Res 71:634.
- Kubo S. ( 1987). Study on the mechanism of marginal fracture of the posterior composite resin. Part 1. Relation between cavity wall adhesion of the resins and marginal fracture. Jpn J Conserv Dent 62:13-27.
- Lambrechts P., Vanherle G., Vuylsteke M., Davidson CL (1984). Quantitative evaluation of the wear resistance of posterior dental restorations: a new three-dimensional measuring technique. J Dent 12:252-267.[Medline]
[Order article via Infotrieve]
- Leinfelder KF (1987). Wear patterns and rates of posterior composite resins. Int Dent J 37:152-157.[Medline]
[Order article via Infotrieve]
- Leinfelder KF (1988). Current developments in posterior composite resins. Adv Dent Res 2:115-121.[Abstract/Free Full Text]
- Leinfelder KF, Broome JC (1994). In vitro and in vivo evaluation of a new universal composite resin. J Esthet Dent 6:177-183.[Medline]
[Order article via Infotrieve]
- Leinfelder KF, Isenberg BP, Wright WW, Teixeira LC, Wisniewski JF (1989). Clinical evaluation of a posterior composite resin containing a semiporous filler particle. Am J Dent 2:36-41.[Medline]
[Order article via Infotrieve]
- Lutz F., Phillips RW, Roulet JF, Setcos JC (1984). In vivo and in vitro wear of potential posterior composites. J Dent Res 63:914-920.
- Mair LH, Vowles RW, Cunningham J., Williams DF (1990). The clinical wear of three posterior composites. Br Dent J 169:355-360.[Medline]
[Order article via Infotrieve]
- Mazer RB, Leinfelder KF (1992). Evaluating a microfill posterior composite resin: a five-year study. J Am Dent Assoc 123:32-38.[Abstract]
- Mazer RB, Leinfelder KF, Russell CM (1992). Degradation of microfilled posterior composite. Dent Mater 8:185-189.[Medline]
[Order article via Infotrieve]
- Mitchem JC, Gronas DG (1985). The continued in vivo evaluation of the wear of restorative resins. J Am Dent Assoc 111:961-964.[Medline]
[Order article via Infotrieve]
- Mitchem JC, Gronas DG (1990). The use of dentures for the evaluation of the abrasive wear of composites (abstract). J Dent Res 69:126.
- Shintani H., Satou N., Satou J. (1989). Clinical evaluation of two posterior composite resins retained with bonding agents. J Prosthet Dent 62:627-632.[Medline]
[Order article via Infotrieve]
- Stangel I., Barolet RY (1990). Clinical evaluation of two posterior composite resins: two-year results. J Oral Rehabil 17:257-268.[Medline]
[Order article via Infotrieve]
- Suzuki S., Leinfelder KF (1993). Localized wear and marginal integrity of posterior resin composites. Am J Dent 6:199-203.[Medline]
[Order article via Infotrieve]
- Tyas MJ, Truong VT, Goldman M., Beech DR (1989). Clinical evaluation of six composite resins in posterior teeth. Austr Dent J 34:147-153.
- Wendt SL Jr, Leinfelder KF (1990). The clinical evaluation of heat-treated composite resin inlays. J Am Dent Assoc 120:177-181.[Abstract]
- Wilder AD, Bayne SC, May KN, Leinfelder KF, Taylor DF (1991). Five-year clinical study of UV-polymerized posterior composites. J Dent 19:214-220.[Medline]
[Order article via Infotrieve]
Journal of Dental Research, Vol. 76, No. 8,
1508-1516 (1997)
DOI: 10.1177/00220345970760081401

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
C. Yue, D. Tantbirojn, R. L. Grothe, A. Versluis, J. S. Hodges, and R. J. Feigal
The Depth of Cure of Clear Versus Opaque Sealants as Influenced by Curing Regimens
J Am Dent Assoc,
March 1, 2009;
140(3):
331 - 338.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R. PERRY, G. KUGEL, K.-H. KUNZELMANN, H.-P. FLESSA, and D. ESTAFAN
COMPOSITE RESTORATION WEAR ANALYSIS: CONVENTIONAL METHODS VS. THREE-DIMENSIONAL LASER DIGITIZER
J Am Dent Assoc,
October 1, 2000;
131(10):
1472 - 1477.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H.H.K. Xu, E. Eichmiller, A.A. Giuseppetti, L.K. Ives, E.E. Parry, and G.E. Schumacher
Three-body Wear of a Hand-consolidated Silver Alternative to Amalgam
Journal of Dental Research,
September 1, 1999;
78(9):
1560 - 1567.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
H.H.K. Xu
Dental Composite Resins Containing Silica-fused Ceramic Single-crystalline Whiskers with Various Filler Levels
Journal of Dental Research,
July 1, 1999;
78(7):
1304 - 1311.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
H.H.K. Xu, T.A. Martin, J.M. Antonucci, and E. Eichmiller
Ceramic Whisker Reinforcement of Dental Resin Composites
Journal of Dental Research,
February 1, 1999;
78(2):
706 - 712.
[Abstract]
[PDF]
|
 |
|
|
|