The effects of various chewing pressures on the wear of composites and enamel were assessed in vitro. Standardized composite discs (8 mm in diameter, 2 mm in height) were made of a fine-particle hybrid (FPH), a coarse-particle hybrid (CPH), and ahomogeneous microfilled composite (HMC). The composite specimens were chemically degraded by immersion in 75% ethanol for 24 h, brushed for 30 min, and then thermocycled 300 times (5-55-5°C) while being occlusally loaded 120,000 times at 1.7 Hz, with chewing forces of 25, 50, 75, and 100 N. Standardized human enamel cusps with a uniform contact area of 0.384 mm2 served as antagonists in the chewing machine. Wear of the composites and enamel cusps, their combined wear, and the increase of the enamel contact surfaces were quantified. An increase in chewing pressure significantly enhanced the wear of both composite and enamel in all groups except for the antagonists opposing a HMC. The FPH was most wear-resistant to in vitro chewing pressures in the range of 6.58 to 19.74 MN/m2, the CPH at 26.32 MN/m2, while the HMC was the most enamel-friendly of the three composites tested. The FPH composite had the least disintegration in the occlusal contact area. The ranking of the composites generally varied at the different chewing pressures with respect to the three types of quantified wear-that is, composite wear, enamel wear, and total wear.
REFERENCES
- Bailey WF, Rice SL ( 1981). Comparative sliding wear behavior of a dental amalgam and a composite restorative as a function of contact stress. J Dent Res 60:731-732.[Free Full Text]
- Bailey WF, Rice SL, Albert RJ, Temin SC (1981). Influence of contact stress, sliding velocity, and surface roughness on the sliding wear of a composite restorative. J Dent Res 60:914-918.[Abstract/Free Full Text]
- Braem M., Lambrechts P., van Doren V., Vanherle G. (1986). In vivo evaluation of four posterior composites: quantitative wear measurements and clinical behaviour. Dent Mater 2:106-113.[CrossRef][Medline]
[Order article via Infotrieve]
- Chapman RJ, Nathanson D. (1983). Excessive wear of natural tooth structure by opposing composite restorations. J Am Dent Assoc 106:51-53.[Abstract]
- Craig RG, Powers JW (1976). Wear of dental tissues and materials. Int Dent J 26:121-133.[Medline]
[Order article via Infotrieve]
- DeGee AJ, Pallav P., Davidson CL (1986). Effect of abrasion medium on wear of stress-bearing composites and amalgam in vitro. J Dent Res 65:654-658.[Abstract/Free Full Text]
- DeLong R., Douglas WH (1983). Development of an artifical oral environment for the testing of dental restoratives: bi-axial force and movement control. J Dent Res 62:32-36.[Abstract/Free Full Text]
- Graber G., Pfaendler U. (1980). Die quintessenz einer praxisbezogenen kronen- und briickenprothetik. Berlin (Germany): Quintessenz.
- Harrison A., Moores GE (1985). Influence of abrasive particle size and contact stress on the wear rate of dental restorative materials. Dent Mater 1:15-17.[Medline]
[Order article via Infotrieve]
- Krejci I., Reich T., Lutz F., Albertoni M. (1990a). In-vitro-testverfahren zur evaluation dentaler restaurationen: 1. computergesteuerter kausimulator. Schweiz Monatsschr Zahnmed 100:953-960.[Medline]
[Order article via Infotrieve]
- Krejci I., Lutz F., Albertoni M. (1990b). In-vitro-testverfahren zur evaluation dentaler restaurationen: 2. zahnbürsten-/zahnpastaabrasion und chemische degradation. Schweiz Monatsschr Zahnmed 100:1164-1168.[Medline]
[Order article via Infotrieve]
- Krejci I., Krejci D., Lutz F. ( 1990c). P-30: in vivo untersuchung eines seitenzahnkomposits wahrend 2,5 jahren. Dtsch Zahnärztl Z 45:773-778.
- Krejci I., Lutz F. ( 1990). In-vitro-testverfahren zur evaluation dentaler restaurationen: 3. korrelation mit in-vivo-resultaten. Schweiz Monatsschr Zahnmed 100:1445-1449.[Medline]
[Order article via Infotrieve]
- Krejci I. (1991). Toothcolored adhesive inlays. Zurich (Switzerland): PZMPARKAR-Verlag, 62-111.
- Lambrechts P. (1983). Basic properties of dental composites and their impact on clinical performance (thesis). Leuven (Belgium).
- Leinfelder KL, Taylor DF, Barkmeier WW, Goldberg AJ (1986). Quantitative wear measurements of posterior composite resins. Dent Mater 2:198-201.[CrossRef][Medline]
[Order article via Infotrieve]
- Lutz F., Phillips RW (1983). A classification and evaluation of composite resin systems. J Prosthet Dent 50:480-488.[CrossRef][Medline]
[Order article via Infotrieve]
- Lutz F., Phillips RW, Roulet JF, Setcos JC (1984). In vivo and in vitro wear of potential posterior composites. J Am Dent Assoc 63:914-920.
- Meier C., Lutz F. ( 1979). Komposits contra amalgam: vergleichende verschleissfestigkeitsmessungen in vivo: 1-jahres-resultate. Schweiz Monatsschr Zahnmed 89:203-212.
- Pallav P., Davidson CL, DeGee AJ (1988). Wear rates of composites, an amalgam, and enamel under stress-bearing conditions. J Prosthet Dent 59:426-429.[CrossRef][Medline]
[Order article via Infotrieve]
- Roulet J.-F (1987). Degradation of dental polymers. Basel (Switzerland): Karger.
- Ryge G. ( 1980). Clinical criteria. Int Dent J 30:347-358. Sakaguchi RL, Douglas WH, DeLong R., Pintado MR (1986). The wear of posterior composite in an artificial mouth: a clinical correlation. Dent Mater 2:235-240.[CrossRef][Medline]
[Order article via Infotrieve]
- Sarrett DC, Soderholm K-JM, Batich CD (1991). Water and abrasive effects on three-body wear of composites. J Dent Res 70:1074-1081.[Abstract/Free Full Text]
- Wilson Nhf (1990). The evaluation of materials: relationship between laboratory investigations and clinical studies. Oper Dent 15:149-155.[Medline]
[Order article via Infotrieve]
- Wu W., McKinney JE (1982). Influence of chemicals on wear of dental composites. J Dent Res 61:1180-1183.[Abstract/Free Full Text]
Journal of Dental Research, Vol. 71, No. 8,
1525-1529 (1992)
DOI: 10.1177/00220345920710081201

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
G. J. Christensen
Remaining challenges with Class II resin-based composite restorations
J Am Dent Assoc,
November 1, 2007;
138(11):
1487 - 1489.
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
H.H.K. Xu, E. Eichmiller, A.A. Giuseppetti, L.K. Ives, E.E. Parry, and G.E. Schumacher
Three-body Wear of a Hand-consolidated Silver Alternative to Amalgam
Journal of Dental Research,
September 1, 1999;
78(9):
1560 - 1567.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
I. Krejci, P. Albert, and F. Lutz
The Influence of Antagonist Standardization on Wear
Journal of Dental Research,
February 1, 1999;
78(2):
713 - 719.
[Abstract]
[PDF]
|
 |
|
|
|