Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

CiteULike is a free service for managing and discovering scholarly references - click here to get started.

Sign In to gain access to subscriptions and/or personal tools.
Journal of Dental Research
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Huysmans, M.C.D.N.J.M.
Right arrow Articles by Soltesz, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huysmans, M.C.D.N.J.M.
Right arrow Articles by Soltesz, U.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Fatigue Behavior of Direct Post-and-core-restored Premolars

M.C.D.N.J.M. Huysmans

Department of Cariology & Endodontology, TRIKON: Institute for Dental Clinical Research, University of Nijmegen, PO Box 9101, 6500 HB Nijmegen, The Netherlands

P.G.T. Van Der Varst

Department of Cariology & Endodontology, TRIKON: Institute for Dental Clinical Research, University of Nijmegen, PO Box 9101, 6500 HB Nijmegen, The Netherlands

R. Schäfer

Fraunhofer-Institut für Werkstoffmechanik, Wöhlerstraße 11, 7800 Freiburg, Germany

M.C.R.B. Peters

Department of Cariology & Endodontology, TRIKON: Institute for Dental Clinical Research, University of Nijmegen, PO Box 9101, 6500 HB Nijmegen, The Netherlands

A.J.M. Plasschaert

Department of Cariology & Endodontology, TRIKON: Institute for Dental Clinical Research, University of Nijmegen, PO Box 9101, 6500 HB Nijmegen, The Netherlands

U. Soltesz

Fraunhofer-Institut für Werkstoffmechanik, Wöhlerstraße 11, 7800 Freiburg, Germany

Evaluation of long-term mechanical behavior of new types of restorations in clinical trials is time-consuming. A partial alternative can be found in experimental fatigue-testing, which simulates accelerated mechanical deterioration. The aim of this study was to determine the feasibility of using fatigue-testing of a complex dental restoration and to evaluate the mechanical fatigue behavior of premolar teeth restored with a titanium alloy post and an amalgam or composite core. Eighty-seven human upper premolar teeth were decoronated, embedded, and restored with a prefabricated post of 1 mm diameter. The teeth were randomly assigned to one of two groups corresponding with a core build-up of amalgam or chemically-cured core composite, respectively. Five to 21 days after restoration, the specimens were subjected to cyclic loading (frequency, 5 Hz), at an angle of 45 degrees to the long axis of the tooth. The boundary technique was used for determination of the mean fatigue strengths of the restorations at 104, 105, and 106 cycles, simulating up to 1-3 years of clinical functioning. Mean fatigue strength was expressed in percentage of initial strength: For 10 4, 105, and 106 cycles, the results were 66%, 58%, and 52%, respectively, for the amalgam and 62%, 62%, and 53% for the composite group. It is concluded that fatigue-testing of more complex systems is possible, if a suitable testing method is selected. The restorations showed a comparable strength reduction after 106 cycles of about 50% of their initial strength. The composite core build-up showed a behavior less predictable than that of the amalgam, which might be attributed to handling parameters.

REFERENCES

  • Anderson DJ (1956). Measurement of stress in mastication. II. J Dent Res 35:671-673.[Free Full Text]
  • Asmussen E., Jörgensen KD (1982). Fatigue strength of some resinous materials. Scand J Dent Res 90:76-79.[Medline] [Order article via Infotrieve]
  • Bates JF, Stafford GD, Harrison A. (1975). Masticatory function-a review of the literature. (II) Speed of movement of the mandible, rate of chewing and forces developed in chewing. J Oral Rehabil 2:349-361.[CrossRef]
  • Chan RW, Bryant RW (1982). Post-core foundations for endodontically treated posterior teeth. J Prosthet Dent 48:401-406.[CrossRef][Medline] [Order article via Infotrieve]
  • Dixon WJ, Mood AM ( 1948). A method for obtaining and analyzing sensitivity data. J Am Stat Assoc 43:108-126.
  • Draughn RA (1979). Compressive fatigue limits of composite restorative materials. J Dent Res 58:1093-1096.[Abstract/Free Full Text]
  • Draughn RA (1985). Fatigue and fracture mechanics of composite resins. In: Vanherle G, Smith DC, editors. Posterior composite resin dental restorative materials. Minneapolis (MN): Minnesota Mining & Mfg. Co., 299-307.
  • Drummond JL (1989). Cyclic fatigue of composite restorative materials. J Oral Rehabil 16:509-520.[CrossRef][Medline] [Order article via Infotrieve]
  • Gelfand M., Goldman M., Sunderman EJ (1984). Effect of complete veneer crowns on the compressive strength of endodontically treated posterior teeth. J Prosthet Dent 52:635-638.[CrossRef][Medline] [Order article via Infotrieve]
  • Gordon M., Metzger Z. (1987). Resistance to horizontal forces of dowel and amalgam-core restorations: a comparative study. J Oral Rehabil 14:337-344.[CrossRef][Medline] [Order article via Infotrieve]
  • Greenfeld RS, Roydhouse RH, Marshall FJ, Schoner B. (1989). A comparison of two post systems under applied compressive-shear loads. J Prosthet Dent 61:17-24.[CrossRef][Medline] [Order article via Infotrieve]
  • Hahnel L., Soltesz U., Klaiber B. (1986). Festigkeitsverhalten von kompositen unter wechsellast-einfluss von prufverfahren, frequenz und umgebung. Laboratory report W4/86. Freiburg: Fraunhofer-Institut für Werkstoffmechanik.
  • Hoag EP, Dwyer TG (1982). A comparative evaluation of three post and core techniques. J Prosthet Dent 47:177-181.[CrossRef][Medline] [Order article via Infotrieve]
  • Huysmans Mcdnjm, Peters Mcrb, Plasschaert Ajm, Van der Varst Pgt (1992). Failure characteristics of endodontically treated premolars restored with a post and direct restorative material. Int Endodont J (accepted for publication).
  • Laurell L., Lundgren D. (1984). A standardized programme for studying the occlusal force pattern during chewing and biting in prosthetically restored dentitions. J Oral Rehabil 11:39-44.[CrossRef][Medline] [Order article via Infotrieve]
  • Little RE (1975). Fatigue strength and fatigue limit tests. In: Wheeler JB, editor. Manual on statistical planning and analysis of fatigue experiments. Lutherville-Timonium (MD): American Society for Testing and Materials, 52-60.
  • Maennig WW (1970). Bemerkungen zur beurteilung des dauerschwingfestigkeitsverhaltens von stahl und einige untersuchungen zur bestimmung des dauerfestigkeitsbereich. Materialprüf 12:124-131.
  • McCabe JF, Ogden AR (1987). The relationship between porosity, compressive fatigue limit and wear in composite resin restorative materials. Dent Mater 3:9-12.[CrossRef][Medline] [Order article via Infotrieve]
  • McCabe JF, Carrick TE, Chadwick RG, Walls Awg (1990). Alternative approaches to evaluating the fatigue characteristics of materials. Dent Mater 6:24-28.[CrossRef][Medline] [Order article via Infotrieve]
  • Newburg RE, Pameijer CH (1976). Retentive properties of post and core systems. J Prosthet Dent 36:637-643.
  • Oden A., Ruyter IE, Qys&d H. (1988). Creep and recovery of composites for use in posterior teeth during static and dynamic loading. Dent Mater 4:147-150.[CrossRef][Medline] [Order article via Infotrieve]
  • Renggli HH, Mühlemann HR, Rateitschak KH (1983). Parodontologie. 3rd ed. Stuttgart (Germany): Georg Thieme Verlag, 44.
  • Ricker JB, Lautenschlager EP, Greener EH (1986). Mechanical properties of post and core systems. Dent Mater 2:63-66.[CrossRef][Medline] [Order article via Infotrieve]
  • Saunders WP (1987). The effect of fatigue impact forces upon the retention of various designs of resin-retained bridgework. Dent Mater 3:85-89.[Medline] [Order article via Infotrieve]
  • Schwickerath H., Nolden R. (1982). Der einfluss des E-moduls von füllungswerkstoffen aufderrandspalt unterdauerbeanspruchung. Dtsch Zahnärztl Z 37:442-444.
  • Soltesz U., Klaiber B., Hahnel L. (1985). Wechsellastverhalten von zwei kompositen unter simulation physiologischer bedingungen. Dtsch Zahnärztl Z 40:902-906.[Medline] [Order article via Infotrieve]
  • Sorensen JA, Martinoff JT (1984). Clinically significant factors in dowel design. J Prosthet Dent 52:28-35.[CrossRef][Medline] [Order article via Infotrieve]
  • Standlee JP, Caputo AA, Hanson EC (1978). Retention of endodontic dowels: effect of cement, dowel length, diameter, and design. J Prosthet Dent 39:401-405.[CrossRef]
  • Stewart GP, Balda BA, Norman RD (1986). The effects of mechanical loading on marginal integrity of composite restorations. Dent Mater 2:151-152.[CrossRef][Medline] [Order article via Infotrieve]
  • Sutow EJ, Jones DW, Hall GC, Milne EL (1985). The response of dental amalgam to dynamic loading. J Dent Res 64:62-66.[Abstract/Free Full Text]
  • Wegmann U., Grüner M. (1987). Die stabilitat von wurzelstiftsystemen im wechsellastversuch. Dtsch Zahnärztl Z 42:334-337.[Medline] [Order article via Infotrieve]
  • Wilkinson EC, Haack DC (1958). A study of the fatigue characteristics of silver amalgam. J Dent Res 37:136-143.[Free Full Text]
  • Zammert WU (1981). Versuchsmethoden zur ermittlung von dauerschwingfestigkeiten. Materialprüf 23:335-339.
  • Zardiackas LD, Bayne SC (1985). Fatigue characterization of nine dental amalgams. Biomaterials 6:49-54.[CrossRef][Medline] [Order article via Infotrieve]

Journal of Dental Research, Vol. 71, No. 5, 1145-1150 (1992)
DOI: 10.1177/00220345920710050301


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
JDRHome page
P.G.T. Van Der Varst, W.A.M. Brekelmans, J.H.P. De Vree, and R. De Groot
Mechanical Performance of a Dental Composite: Probabilistic Failure Prediction
Journal of Dental Research, August 1, 1993; 72(8): 1249 - 1256.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Huysmans, M.C.D.N.J.M.
Right arrow Articles by Soltesz, U.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Huysmans, M.C.D.N.J.M.
Right arrow Articles by Soltesz, U.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?