|
Sign In to gain access to subscriptions and/or personal tools.
|
Water and Abrasive Effects on Three-body Wear of Composites
D.C. Sarrett
Department of Operative Dentistry, PO Box 100415
K.-J.M. Söderholm
Department of Dental Biomaterials, PO Box 100446, University of Florida, Gainesville, FL 32610
C.D. Batich
Department of Materials Science and Engineering, University of Florida, Gainesville, FL 32611
The degrees of in vitro three-body wear resistance of a hybrid, a small-particle, and a microfilled composite were determined after water storage for up to 24 months. The hybrid composite was the most wear-resistant, while the microfilled composite showed the most wear. The hybrid composite showed no loss of wear resistance as a result of water storage. The small-particle composite showed a decrease in wear resistance after water storage only when tested with silicon carbide abrasive. The wear resistance of the microfilled composite decreased following water storage when tested with either a soft (CaCO3) or a hard (SiC) abrasive. For all composites, the soft abrasive was not capable of causing preferential wear of the polymer matrix, as observed on in vivo specimens. Instead, the filler particles became flattened, with minimal loss of interparticle substance. The hard abrasive did cause preferential wear of the matrix. All composites absorbed water and leached silicon during water storage, indicating that the filler-polymer bond was attacked by hydrolytic degradation. Scanning electron microscopic evaluation of the three-body wear specimens indicated that the in vitro wear method did not duplicate in vivo wear conditions (e.g., the hard abrasive caused excessive wear and chipping of the filler particles in vitro, a pattern that was not usually observed in vivo). Filler-polymer de-bonding was observed on in vivo specimens of all the composites, while it was found only on the in vitro microfilled composite specimens. These findings suggest that filler dislodging is a complex process that cannot be simulated with the in vitro wear method used in this study, not even after prolonged water storage.
REFERENCES
- Abell, A.K.; Leinfelder, K.F.; and Turner, D.T. (1983): Microscopic Observations of the Wear of a Tooth Restorative Composite in vivo, J Biomed Mater Res 17:501-507.[CrossRef][Medline]
[Order article via Infotrieve]
- Braden, M.; Causton, E.E.; and Clarke, R.L. (1976): Diffusion of Water in Composite Filling Materials, J Dent Res 55:730-732.[Abstract/Free Full Text]
- Chadwick, R.G.; McCabe, J.F.; Walls, A.W.G.; and Storer, R. (1990): The Effect of Storage Media upon the Surface Microhardness and Abrasion Resistance of Three Composites, Dent Mater 6:123-128.[CrossRef][Medline]
[Order article via Infotrieve]
- Craig, R.G. and Powers, J.M. (1976): Wear of Dental Tissues and Materials, Int Dent J 26:121-133.[Medline]
[Order article via Infotrieve]
- Eames, W.B.; Strain, J.D.; Weitman, R.T.; and Williams, A.K. (1974): Clinical Comparison of Composite, Amalgam, and Silicate Restorations, J Am Dent Assoc 89:1111-1117.[Medline]
[Order article via Infotrieve]
- Ehrnford, L.; Derand, T.; Larsson, L.-Å.; and Svensson, A. (1980): An Abrasion Test for Composite Resins, J Dent Res 59:716-720.[Abstract/Free Full Text]
- Foster, L.S. (1970): Comparison of Hardness Values of Various Materials on Mohs and Knoop Scales. In: Handbook of Chemistry and Physics, 51st ed., R.C. Weast, Ed., Cleveland: The Chemical Rubber Co., p. F-18.
- Jorgensen, K.D. (1980): Restorative Resins: Abrasion vs. Mechanical Properties, Scand J Dent Res 88:557-568.[Medline]
[Order article via Infotrieve]
- Jrgensen, K.D. (1982): In vitro Wear Tests on Macro-filled Composite Restorative Materials, Aust Dent J 27:153-158.[Medline]
[Order article via Infotrieve]
- Kelly, A. (1970): Interface Effects on the Work of Fracture of a Fibrous Composite, Proc R Soc Lond (A) 319:95-116.[Abstract/Free Full Text]
- Kusy, R.P. and Leinfelder, K.F. (1977): Pattern of Wear in Posterior Composite Restorations, J Dent Res 56:544.[Free Full Text]
- Leinfelder, K.F.; Sluder, T.B.; Sockwell, C.L.; Strickland, W.D.; and Wall, J.T. (1975): Clinical Evaluation of Composite Resins as Anterior and Posterior Restorative Materials, J Prosthet Dent 33:407-416.[CrossRef][Medline]
[Order article via Infotrieve]
- Moffa, J.P.; Jenkins, W.A.; and Hamilton, J.C. (1984): The Longevity of Composite Resins for the Restoration of Posterior Teeth, J Dent Res 63 (Spec Iss A):199, Abst. No. 253.
- MONTES-G, G.M. and Draughn, R.A. (1986): In vitro Surface Degradation of Composites by Water and Thermal Cycling, Dent Mater 2:193-197.[CrossRef][Medline]
[Order article via Infotrieve]
- O'Brien, W.J. and Yee, J. (1980): Microstructure of Posterior Restorations of Composite Resin After Clinical Wear, Oper Dent 5:90-94.[Medline]
[Order article via Infotrieve]
- Phillips, R.W.; Avery, D.R.; Mehra, R.; Swartz, M.L.; and McCune, R.J. (1971): One-Year Observations on a Composite Resin for Class II Restorations, J Prosthet Dent 26:68-77.[CrossRef][Medline]
[Order article via Infotrieve]
- Phillips, R.W.; Avery, D.R.; Mehra, R.; Swartz, M.L.; and McCune, R.J. (1972): Observations on a Composite Resin for Class II Restorations: Two-year Report, J Prosthet Dent 28:164-169.[CrossRef][Medline]
[Order article via Infotrieve]
- Phillips, R.W.; Avery, D.R.; Mehra, R.; Swartz, M.L.; and McCune, R.J. (1973): Observations on a Composite Resin for Class II Restorations: Three-year Report, J Prosthet Dent 30:891-897.[CrossRef][Medline]
[Order article via Infotrieve]
- Pilliar, R.M.; Smith, D.C.; and Maric, B. (1984): Oscillatory Wear Tests of Dental Composites, J Dent Res 63:1166-1172.[Abstract/Free Full Text]
- Prasad, S.V. and Calvert, P.D. (1980): Abrasive Wear of Particle-filled Polymers, J Mater Sci 15:1746-1754.[CrossRef]
- Sarrett, D.C. (1988): Wear Behavior of Dental Composite Resin Restorative Materials, Gainesville, FL: University of Florida, M.S. Thesis, pp. 11-27.
- Sas Institute, Inc. (1985): SAS User's Guide: Statistics, Version 5 ed., Cary, NC: Publications Division, SAS Institute, Inc., pp. 171-172.
- Soderholm, K.-J. (1981): Degradation of Glass Filler in Experimental Composites, J Dent Res 60:1867-1875.[Abstract/Free Full Text]
- Soderholm, K.-J.M. (1983): Leaking of Fillers in Dental Composites, J Dent Res 62:126-130.[Abstract/Free Full Text]
- Soderholm, K.-J.M. (1984): Hydrolytic Degradation of Dental Composites and Effects of Silane-Treatment and Filler Fraction on Compressive Strength and Thermal Expansion of Composites, Umeå, Sweden: Umeå University Odontological Dissertations No. 19, ISSN 0345-7532, pp. 1-165.
- Söderholm, K.-J.M. and Roberts, M.J. (1990): Influence of Water Exposure on the Tensile Strength of Composites, J Dent Res 69:1812-1816.[Abstract/Free Full Text]
- Söderholm, K.-J.; Zigan, M.; Ragan, M.; Fischlschweiger, W.; and Bergman, M. (1984): Hydrolytic Degradation of Dental Composites, J Dent Res 63:1248-1254.[Abstract/Free Full Text]
- Zinns, D.; Maric, B.; Pilliar, R.M.; and Smith, D.C. (1982): Oscillatory Wear Studies of Composite Resins, IADR Prog & Abst 61: No. 457.
Journal of Dental Research, Vol. 70, No. 7,
1074-1081 (1991)
DOI: 10.1177/00220345910700071201

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
F. Lutz, I. Krejci, and F. Barbakow
Chewing Pressure us. Wear of Composites and Opposing Enamel Cusps
Journal of Dental Research,
August 1, 1992;
71(8):
1525 - 1529.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
A.M. Diaz-Arnold, M.A. Arnold, and V.D. Williams
Measurement of Water Sorption by Resin Composite Adhesives with Near-Infrared Spectroscopy
Journal of Dental Research,
March 1, 1992;
71(3):
438 - 442.
[Abstract]
[PDF]
|
 |
|
|
|