Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Journal of Dental Research
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Mair, L.H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mair, L.H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Staining of in vivo Subsurface Degradation in Dental Composites with Silver Nitrate

L.H. Mair

Department of Clinical Dental Sciences, University of Liverpool, P.O. Box 147, Liverpool L69 3BX, United Kingdom

A previously reported technique for staining areas of degradation in dental composite restorations was evaluated in 51 removed restorations. The staining reagent was silver nitrate, which penetrated the degraded subsurface as ionic silver and was subsequently developed into colored deposits of metallic silver. Several artefacts were recognized that resulted in an apparent image of subsurface stain. Most importantly, the presence of a layer of adsorbed silver on the edge of the specimen exaggerated the extent of staining. In order for the true depth of stain to be determined, thin sections of the materials should first be examined with a stereomicroscope to distinguish any contribution from adsorbed silver on the specimen edge. With this regimen, no stain was present in 41% of the restorations, and in a further 30%, the depth of stain was less than 50 µm. In two composites, the depth of stain was greater than 900 µm, and in a number of specimens, localized stain was found in association with attrition scars. Energy-dispersive x-ray analysis indicated that the amount of silver present in the degraded layers was very small. Overall, the results indicated that the staining technique is useful in the study of composite degradation.

REFERENCES

  • Birchton, D. (1961): Preparation of Specimens for Examination by Reflected Light Microscopy. In: Optical Microscope Technique, London: Newnes, pp. 189-195.
  • Braden, M. and Pearson, G.J. (1981): Analysis of Aqueous Extract from Filled Resins, J Dent 9:141-143.[CrossRef][Medline] [Order article via Infotrieve]
  • Chase, W. and Bown, F. (1986): Inference Concerning Two Population Parameters. In: General Statistics, New York: Wiley & Sons, pp. 352-383.
  • Culling, C.F.A. (1974): The Darkground Microscope. In: Modern Microscopy, Elementary Theory and Practice, London: Butterworths, pp. 39-42.
  • Eakle, W.S. and Ito, R.K. (1990): Effect of Insertion Technique on Microleakage in Mesio-occlusodistal Restorations, Quint Int 21:369-374.
  • Fan, P.L.; Edahl, A.; Leung, R.L.; and Stanford, J.W. (1985): Alternative Interpretations of Water Sorption Values of Composite Resins, J Dent Res 64:78-80.[Abstract/Free Full Text]
  • Hammesfahr, P.D.; Huang, C.T.; and Snaffer, S.E. (1987): Microleakage and Bond Strength of Resin Restorations with Various Bonding Agents, Dent Mater 3:194-199.[CrossRef][Medline] [Order article via Infotrieve]
  • Lambrechts, P.; Vanherle, G.; Vuylsteke, M.; and Davidson, C.L. (1984): Quantitative Evaluation of the Wear Resistance of Posterior Dental Restorations: a New Three Dimensional Measuring Technique, J Dent 12:252-267.[CrossRef][Medline] [Order article via Infotrieve]
  • Langford, M.J. (1974): The Sensitive Material. In: Basic Photography, London: Focus Press, pp. 153-157.
  • Leidal, T.I.; Solem, H.; and Rykke, M. (1985): A Clinical and Scanning Electron Microscope Study of a New Restorative Material for Use in Posterior Teeth, Acta Odontol Scand 43:1-8.[CrossRef][Medline] [Order article via Infotrieve]
  • Mair, L.H. (1989a): Permeability, Degradation and Wear of Dental Composites, Ph.D. Thesis, University of Liverpool.
  • Mair, L.H. (1989b): An Investigation into the Permeability of Composite Materials, Dent Mater 5:109-111.[CrossRef][Medline] [Order article via Infotrieve]
  • Montes-G., M. and Draughn, R.A. (1986): In vitro Surface Degradation of Composites by Water and Thermal Cycling, Dent Mater 2:193-197.[CrossRef][Medline] [Order article via Infotrieve]
  • Oysaed, H. and Ruyter, I.E. (1986): Composites for Use in Posterior Teeth: Mechanical Properties Tested Under Wet and Dry Conditions, J Biomed Mater Res 20:261-267.[CrossRef][Medline] [Order article via Infotrieve]
  • Richardson, J.H. (1971): Photomicroscopy. In: Optical Microscopy for the Material Sciences, New York: Dekker Inc., pp. 203-210.
  • Robinson, G. (1982): Theoretical Aspects of Instrumentation. In: Theory & Practice of Histological Techniques, J. Bancroft and A. Stevens, Eds., Edinburgh: Churchill Livingston, pp. 467-468.
  • Rose, R.A. (1982): Light Microscopy. In: Theory & Practice of Histological Techniques, J. Bancroft and A. Stevens, Eds., Edinburgh: Churchill Livingston, pp. 1-19.
  • Roulet, J.F. (1987): Development of Appropriate Measuring Devices. In: Degradation of Dental Polymers, Basel: Karger, pp. 92-113.
  • Rueggeberg, F.A. and Craig, R.G. (1988): Correlation of Parameters used to Estimate Monomer Conversion in a Light-cured Composite, J Dent Res 67:932-937.[Abstract/Free Full Text]
  • Sawyer, L.C. and Grubb, D.T. (1987): Specimen Preparation Methods. In: Polymer Microscopy, London: Chapman and Hall, pp. 45-89.
  • Soderholm, K.-J. (1981): Degradation of Glass Fillers in Experimental Composites, J Dent Res 60:1867-1875.[Abstract/Free Full Text]
  • Soderholm, K.-J. (1983): Leaking of Fillers in Dental Composites, J Dent Res 62:126-130.[Abstract/Free Full Text]
  • Soderholm, K.-J.; Zigan, M.; Ragan, M.; Fischl-Schweiger, W.; and Bergman, M. (1984): Hydrolytic Degradation of Dental Composites, J Dent Res 63:1248-1254.[Abstract/Free Full Text]
  • Wu, W. and Cobb, E.N. (1981): A Silver Staining Technique for Investigating Wear of Restorative Dental Composites, J Biomed Mater Res 15:343-348.[CrossRef][Medline] [Order article via Infotrieve]
  • Wu, W.; Cobb, E.; Dermann, K.; and Rupp, N.W. (1983): Detecting Margin Leakage of Dental Composite Restorations, J Biomed Mater Res 17:37-43.[CrossRef][Medline] [Order article via Infotrieve]
  • Wu, W.; Toth, E.E.; Moffa, J.F.; and Ellison, J.A. (1984): Subsurface Damage Layer of in vivo Worn Dental Composite Restorations, J Dent Res 63:675-680.[Abstract/Free Full Text]

Journal of Dental Research, Vol. 70, No. 3, 215-220 (1991)
DOI: 10.1177/00220345910700031201


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Journal of the American Dental AssociationHome page
S. B. PATEL, V. V. GORDAN, A. A. BARRETT, and C. SHEN
The effect of surface finishing and storage solutions on the color stability of resin-based composites
J Am Dent Assoc, May 1, 2004; 135(5): 587 - 594.
[Abstract] [Full Text] [PDF]


Home page
ADRHome page
L.H. Mair
Stain and Subsurface Degradation of Dental Composites as a Function of Structure and Permeability: a Clinical and Laboratory Study
Advances in Dental Research, December 1, 1995; 9(4): 457 - 461.
[Abstract] [PDF]


Home page
JDRHome page
J.L. Ferracane, J.R. Condon, and J.C. Mitchem
Evaluation of Subsurface Defects Created During the Finishing of Composites
Journal of Dental Research, September 1, 1992; 71(9): 1628 - 1632.
[Abstract] [PDF]


Home page
JDRHome page
J.L. Ferracane and V.A. Marker
Solvent Degradation and Reduced Fracture Toughness in Aged Composites
Journal of Dental Research, January 1, 1992; 71(1): 13 - 19.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Mair, L.H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Mair, L.H.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?