Transient and Residual Stress in a Porcelain-Metal Strip
K. Asaoka
Department of Dental Engineering, School of Dentistry, Tokushima University, Tokushima, Japan
J.A. Tesk
Dental and Medical Materials, Polymers Division, National Institute of Standards and Technology, Gaithersburg, Maryland 20899
Porcelain-fused-to-metal (PFM) restorations may develop cracks during processing or in-mouth service if the relative physico-mechanical properties of the porcelain and metal are highly mismatched. Precise conditions when this might occur are not known. Many processing and property variations can affect the stresses developed throughout a porcelain-metal system. To understand this, we conducted a computer simulation of stress developed in a PFM beam. The simulation considers cooling from temperatures higher than the porcelain sag-point. The following temperature-dependent factors were incorporated: the elastic modulus, shear viscosity (porcelain), and coefficients of thermal expansion. The cooling rate dependencies of the glass transition temperature, (Tg), and the temperature distribution during cooling were also included.
The results suggest that transient tensile stress at the porcelain alloy interface may result in cracks in the porcelain during cooling. Occlusal forces may set up stresses to cause cracking at the surface of the porcelain if the compressive residual stress is not high enough. PFM restorations with an alloy of high thermal expansion coefficient require rapid cooling; on the contrary, PFM restorations with the alloys of lower coefficients require slow cooling. A high cooling rate can make up for thermal expansion mismatches between the alloy and the porcelain up to 2 x 10-6/°C. Finally, the results indicated that curvature was not a sensitive indication of stress for a multimaterial beam when visco-elastic relaxation and high cooling rates are involved. For the case modeled here, curvature varied inversely with a 1/2 to 1/7th power of the stress.
REFERENCES
- Asaoka, K. (1986): Estimation on Residual Stress in Porcelain/ Alloy System by Thermal Shock Test, Dent Mater J 5:145-157.[Medline]
[Order article via Infotrieve]
- Asaoka, K. and Tesk, J.A. (1987): Residual Stress in Porcelain Related to Cooling Rate, J Dent Res 66:270, Abst. No. 1306.
- Asaoka, K. and Tesk, J.A. (1989): Transient and Residual Stresses in Dental Porcelains as Affected by Cooling Rates, Dent Mater J 8:9-25.[Medline]
[Order article via Infotrieve]
- Bertolotti, R.L. and Fukui, H. (1982): Measurement of Softening Temperatures in Dental Bake-on Porcelains, J Dent Res 61:1066-1069.[Abstract/Free Full Text]
- Bertolotti, R.L. and Shelby, J.E. (1979): Viscosity of Dental Porcelain as a Function of Temperature, J Dent Res 58:2001-2004.[Abstract/Free Full Text]
- Dehoff, P.H. and Anusavice, K.J. (1986): An Analytical Model to Predict the Effects of Heating Rate and Applied Load on Glass Transition Temperatures of Dental Porcelain, J Dent Res 65:643-647.[Abstract/Free Full Text]
- Fairhurst, C.W.; Anusavice, K.J.; Hashinger, D.T.; Ringle, R.D.; and Twiggs, S.W. (1980): Thermal Expansion of Dental Alloys and Porcelains, J Biomed Mater Res 14:435-446.[CrossRef][Medline]
[Order article via Infotrieve]
- Fairhurst, C.W.; Hashinger, D.T.; and Twiggs, S.W. (1981): Glass Transition Temperature of Dental Porcelain, J Dent Res 60:995-998.[Free Full Text]
- Kase, H. and Tesk, J.A. (1984): Elastic Constants of Three Representative Nonprecious Dental Alloys, J Dent Res 63:258, Abst. No. 791.
- Kase, H.R.; Tesk, J.A.; and Case, E.D. (1985): Elastic Constants of Two Dental Porcelains, J Mater Sci 20:524-531.[CrossRef]
- Kingery, W.D.; Bowen, H.K.; and Uhlmann, D.R. (1975): Introduction to Ceramics, New York: John Wiley and Sons, p. 759.
- Moynihan, C.T.; Easteal, A.J.; Wilder, J.; and Tucker, J. (1974): Dependence of the Glass Transition Temperature on Heating and Cooling Rate, J Phys Chem 78:2673-2677.[CrossRef]
- Timoshenko, S. (1925): Analysis of Bimetal Thermostats, J Opt Soc Am 11:233-255.[CrossRef]
- Tesk, J.A.; Hinman, R.W.; Whitlock, R.P.; Holmes, A.; and Parry, E.E. (1981): Temperature Dependence of Shear Viscosity for Several Dental Porcelains, IADR Prog & Abst 59: No. 839.
- Tuccillo, J.J. and Nielsen, J.P. (1972): Shear Stress Measurements at a Dental Porcelain Gold Bond Interface, J Dent Res 51: 626-633.[Abstract/Free Full Text]
- Whitlock, R.P.; Tesk, J.A.; Widera, G.E.O.; Holmes, A.; and Parry, E.E. (1980): Consideration of Some Factors Influencing Compatibility of Dental Porcelains and Alloys, Proc Int Precious Metals Conf 4:273-282.
- Williamson, E.D. and Adams, L.H. (1919): Temperature Distribution in Solids During Hcating or Cooling, Phys Rev 14:99-114.[CrossRef]
Journal of Dental Research, Vol. 69, No. 2,
463-469 (1990)
DOI: 10.1177/00220345900690020901

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
P.H. DeHoff, K.J. Anusavice, and S.B. Vontivillu
Analysis of Tempering Stresses in Metal-Ceramic Disks
Journal of Dental Research,
February 1, 1996;
75(2):
743 - 751.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
K. Asaoka, N. Kuwayama, and J.A. Tesk
Influence of Tempering Method on Residual Stress in Dental Porcelain
Journal of Dental Research,
September 1, 1992;
71(9):
1623 - 1627.
[Abstract]
[PDF]
|
 |
|
|
|