Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Journal of Dental Research
This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Baker, S.
Right arrow Articles by Walker, D.M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, S.
Right arrow Articles by Walker, D.M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

The Release of Residual Monomeric Methyl Methacrylate from Acrylic Appliances in the Human Mouth: An Assay for Monomer in Saliva

S. Baker

Departments of Oral Surgery, Medicine and Pathology, University of Wales College of Medicine, Cardiff, CF4 4XY, United Kingdom

S.C. Brooks

Department of Prosthetic Dentistry, Dental SchoolC

D.M. Walker

Departments of Oral Surgery, Medicine and Pathology, University of Wales College of Medicine, Cardiff, CF4 4XY, United Kingdom

A gas-liquid chromatography assay has been developed for the estimation of methyl methacrylate monomer (MMA) in whole saliva, with a lower limit of detection in the order of 1µg/mL. Healthy human dentate subjects wore recently made autopolymerized or heat-polymerized polymethyl methacrylate (PMMA) palatal appliances. MMA released into saliva was detected for up to one week after insertion of autopolymerized appliances, with a maximum concentration of 45 µg/mL in whole saliva or 180 µg/mL in the salivary film on the fitting surface. The MMA was not detected in blood or urine. MMA was also present in the saliva of volunteers wearing appliances which had been heat-polymerized at 70°C for one hr but not cured at 70°C for three hr. The maximum amount of monomer released by an autopolymerized base plate was 29.5 µg in the first hour, which, while not a toxic or primary irritant dose, could possibly sensitize patients or elicit an allergic reaction. For minimization of monomer release, autopolymerized appliances should be immersed for 24 hr in water before being worn.

REFERENCES

  • Ali, A.; Bates, J.F.; Reynolds, A.J.; and Walker, D.M. (1986): The Burning Mouth Sensation Related to the Wearing of Acrylic Dentures: An Investigation, Br Dent J 161:444-447.[Medline] [Order article via Infotrieve]
  • Austin, A.T. and Basker, R.M. (1982): Residual Monomer in Denture Bases, Br Dent J 152:424-426.
  • Corkill, J.A.; Lloyd, E.J.; Hoyle, P.; Crout, D.H.G.; Ling, R.S.M.; James, M.L.; and Piper, R.J. (1976): Toxicology of Methyl Methacrylate: The Rate of Disappearance of Methyl Methacrylate in Human Blood in vitro, Clin Chim Acta 68:141-146.[CrossRef][Medline] [Order article via Infotrieve]
  • Crissey, J.T. (1965): Stomatitis, Dermatitis and Denture Materials, Arch Dermatol 92:45-48.[Abstract/Free Full Text]
  • Cronin, E. (1980): Contact Dermatitis, Edinburgh: Churchill Livingstone, p. 580.
  • Douglas, W.H. and Bates, J.F. (1978): The Determination of Residual Monomer in Polymethyl Methacrylate Denture Base Resins, J Mater Sci 13:2600-2604.[CrossRef]
  • Eggert, A.; Huland, H.; Ruhnke, J.; and Seidel, A. (1974): Der Ubertritt von Methylmethacrylät-Monomer in die Blutbahn des Menschen nach Huftgelenksersatz Operationen, Chirurg 45:236-242.[Medline] [Order article via Infotrieve]
  • Fisher, A.A. (1954): Allergic Sensitization of the Skin and Oral Mucosa to Acrylic Denture Materials, J Am Med Assoc 156:238-241.[Abstract/Free Full Text]
  • Fisher, A.A. (1956): Allergic Sensitisation of the Skin and Oral Mucosa to Acrylic Denture Materials, J Prosthet Dent 6:593-602.[CrossRef]
  • Giunta, J. and Zablotsky, N. (1976): Allergic Stomatitis Caused by Self-polymerising Resin, Oral Surg 41:631-637.
  • Health And Safety Executive (1986): Occupational Exposure Limits 1986. Guidance Note EH 40/86. London: HMSO.
  • Huggett, R.; Brooks, S.C.; and Bates, J.F. (1984): The Effect of Curing Cycle on Levels of Residual Monomer in Acrylic Resin Denture Base Materials, Quintessence Dent Technol 8:365-371.[Medline] [Order article via Infotrieve]
  • Lamb, D.J.; Ellis, B.; and Priestley, B. (1982): Loss into Water of Residual Monomer from Autopolymerizing Dental Acrylic Resins, Biomaterials 3:155-159.
  • McCabe, J.F. and Basker, R.M. (1976): Tissue Sensitivity to Acrylic Resin. A Method of Measuring the Residual Monomer Contents and its Clinical Application, Br Dent J 140:347-350.[CrossRef][Medline] [Order article via Infotrieve]
  • Osborne, J. and Lammie, G.A. (1974): In: Partial Dentures, 4th ed., Oxford: Blackwell, pp. 399-400.
  • Pantucek, M. (1969): On the Metabolic Pathway of Methyl Methacrylate, FEBS Lett 2:206-209.[Medline] [Order article via Infotrieve]
  • Ruyter, I.E. (1980): Release of Formaldehyde from Denture Base Polymers, Acta Odontol Scand 38:17-27.[Medline] [Order article via Infotrieve]
  • Smith, D.C. and Bains, M.E.D. (1956): The Detection and Estimation of Residual Monomer in Polymethyl Methacrylate, J Dent Res 35:16-24.[Free Full Text]
  • Stafford, G.D. and Brooks, S.C. (1985): The Loss of Residual Monomer from Acrylic Orthodontic Resins, Dent Mater 1: 135-138.[CrossRef][Medline] [Order article via Infotrieve]
  • Stungis, T.E. and Fink, J.N. (1969): Hypersensitivity to Acrylic Resin, J Prosthet Dent 22:425-428.[CrossRef][Medline] [Order article via Infotrieve]

Journal of Dental Research, Vol. 67, No. 10, 1295-1299 (1988)
DOI: 10.1177/00220345880670101001


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
CROBMHome page
J.P. Santerre, L. Shajii, and B.W. Leung
Relation of Dental Composite Formulations To Their Degradation and the Release of Hydrolyzed Polymeric-Resin-Derived Products
Critical Reviews in Oral Biology & Medicine, January 1, 2001; 12(2): 136 - 151.
[Abstract] [Full Text] [PDF]


Home page
ADRHome page
H. R. Stanley
Local and Systemic Responses To Dental Composites and Glass Ionomers
Advances in Dental Research, September 1, 1992; 6(1): 55 - 64.
[Abstract] [PDF]


This Article
Right arrow Abstract Freely available
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Baker, S.
Right arrow Articles by Walker, D.M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baker, S.
Right arrow Articles by Walker, D.M.
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?