|
Sign In to gain access to subscriptions and/or personal tools.
|
Effects of Rare-earth Filters on Patient Exposure and Image Contrast
S.M. Mauriello
Department of Dental Ecology, School of Dentistry, School of Dentistry, University of North Carolina, Chapel Hill, North Carolina 27514
D.B. Washburn
Department of Radiology, School of Medicine, School of Dentistry, University of North Carolina, Chapel Hill, North Carolina 27514
S.R. Matteson
Department of Oral Diagnosis, School of Dentistry, University of North Carolina, Chapel Hill, North Carolina 27514
Minimizing patient exposure while maintaining a diagnostically acceptable radiograph is a major goal in diagnostic radiography. Rare-earth filters may be the means to achieve this goal due to their "bandpass effect". The purpose of this study was to examine the image contrast effects and exposure reductions for various thicknesses of aluminum, samarium, gadolinium, gadolinium oxysulfide, and gadolinium oxysulfide added to 2.5 mm of aluminum. Trials were conducted on an intra-oral dental x-ray unit (range, 65 to 90 kVp). When compared with conventional aluminum, all of the rare-earth filters provided lower radiation exposures, with gadolinium in the metallic or oxysulfide form providing the lowest exposures. Samarium, at a thickness of 0.127 mm, yielded the highest image contrast. Gadolinium or gadolinium oxysulfide added to 2.5 mm of aluminum resulted in a slight loss of contrast when compared with conventional aluminum filtration. This loss may not be clinically significant, and when coupled with the reduced exposure afforded by these filters, they become viable as acceptable alternatives to aluminum filtration.
REFERENCES
- Atkins, H.L.; Fairchild, R.G.; Robertson, J.S.; and Greenberg, D. (1975): Effects of Absorption Edge Filters on Diagnostic X-Ray Spectra, Radiology 115:431-437.[Abstract]
- Burgess, A.E. (1981): Contrast Effects of a Gadolinium Filter, Med Phys 8:203-209.[Medline]
[Order article via Infotrieve]
- Cember, H. (1976): Radiation Protection Guides. In: Introduction to Health Physics, 2nd ed., New York: Pergamon Press, pp. 203-204.
- Chakera, T.M.H.: Fleay, R.F.; Henson, P.W.; and Cole, S.M. (1982): Dose Reduction in Radiology Using Heavy Metal Foils, Br J Radiol 55:853-858.[Abstract/Free Full Text]
- Curry, T.S.; Dowdey, J.E.; and Murray, R.C. (1984): Filters and Filtration. In: Christensen's Introduction to the Physics of Diagnostic Radiology, 3rd ed., Philadelphia: Lea and Febiger, pp. 77-81.
- Dawood, F.F. and Manson-Hing, L.R. (1979): Evaluation of New Radiographic Screens for Intraoral Radiography, Oral Surg 48:178-186.
- Fatouros, P.P.; Gibbs, S.J.; Skubic, S.E., and Rao, G.U.V. (1984): Imaging Characteristics of New Screen/Film Systems for Cephalometric Radiography, Angle Orthod 54:36-54.[Medline]
[Order article via Infotrieve]
- Fleay. R.F. (1980): Energy Band Selection in Radiology by K Absorption Edge Filtration, Aust Radiol 24:323-327.[Medline]
[Order article via Infotrieve]
- Gelskey, D.E. and Baker, C.G. (1981): Energy-selective Filtration of Dental X-ray Beams, Oral Surg 52:565-567.
- Gratt, B.M.; White, S.C.; Packard, B.S.; and Petersson, A.R. (1984): An Evaluation of Rare-earth Imaging Systems in Panoramic Radiography, Oral Surg 58:475-482.
- Gray, J.E.; Norlin, W.; Stears, J.; and Frank, E. (1983): Quality Control in Diagnostic Imaging. Baltimore: University Park Press, pp. 33-49.
- Hurlburt, C.T. (1981): Faster Screen/Film Combinations for Cephalometric Radiography, Oral Surg 52:661-665.
- Hurlburt, C.E. (1984): Rare Earth Screens for Panoramic Radiography, Oral Surg 57:451-454.
- Johnson, M.A. and Burgess, A.E. (1981): Clinical Use of a Gadolinium Filter in Pediatric Radiography, Pediatr Radiol 10:229-232.[Medline]
[Order article via Infotrieve]
- Keur, J.J. (1983): A Rare Earth Screen-Film System for Dental Panoramic Radiography, Aust Dent J 28:105-108.[Medline]
[Order article via Infotrieve]
- Kogon, S.L.; Stephens, T.G.; Reid, J.A.; and Lubus, N.J. (1984): A Clinical Trial of a Rare Earth Screen/Film System in a Periapical Cassette, Oral Surg 57:455-461.
- Ponce, A.Z.; McDavid W.D.; Underhill, T.E.; and Morris, C.R. (1986): Use of E-Speed Film with Added Filtration, Oral Surg 61:297-299.
- Richards, A.G.; Barbor, G.L.; Bader, J.D.; and Hale, J.D. (1970): Samarium Filters for Dental Radiography, Oral Surg 29:704-715.
- Rossi, R.P.; Hendee, W.R.; and Ahrens, C.R. (1976): An Evaluation of Rare Earth Screen/Film Combinations, Radiology 121:465-471.[Medline]
[Order article via Infotrieve]
- Tyndall, D.A. and Washburn, D.B. (1986): Rare-earth Filters in Panoramic Radiography: A Means of Reducing Patient Dose Without Compromising Image Quality, Dentomaxillofac Radiol 15:19-26.[Medline]
[Order article via Infotrieve]
- Venema, H.W. (1979): X-Ray Absorption, Speed, and Luminescent Efficiency of Rare Earth and Other Intensifying Screens, Radiology 130:765-771.[Medline]
[Order article via Infotrieve]
- Villagran, J.E.; Hobbs, B.B.; and Taylor, K.W. (1978): Reduction of Patient Exposure by Use of Heavy Elements as Radiation Filters in Diagnostic Radiology, Radiology 127:249-254.[Abstract]
- Wang, Y.; McArdle, G.H.; Feig, S.A.; Karasick, S.; Koolpe, H.A.; Mapp, E.; Rao, V.M.; Steiner, R.M.; and Wechsler, R.J. (1984): Clinical Applications of Yttrium Filters for Exposure Reduction, Radio-Graphics 4:479-505.
Journal of Dental Research, Vol. 66, No. 8,
1326-1330 (1987)
DOI: 10.1177/00220345870660080701

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
|
|