|
Sign In to gain access to subscriptions and/or personal tools.
|
A Comparison of Four Modes of Evaluating Depth of Cure of Light-activated Composites
J.P. DeWald
Department of Operative Dentistry, Baylor College of Dentistry, 3302 Gaston Avenue, Dallas, Texas 75246
J.L. Ferracane
Department of Dental Materials, Baylor College of Dentistry, 3302 Gaston Avenue, Dallas, Texas 75246
Four commonly used methods for evaluating depth of cure in light-activated composites were compared. Optical and scraping methods correlate well, but severely overestimate depth of cure as compared with hardness testing or degree of conversion analysis. Degree of conversion appears to be the most sensitive test of depth of cure.
REFERENCES
- Asmussen, E. (1982): Restorative Resins: Hardness and Strength vs. Quantity of Remaining Double Bonds, Scand J Dent Res 90:484-489.[Medline]
[Order article via Infotrieve]
- Cook, W. (1980): Factors Affecting the Depth of Cure of Ultra Violet-Polymerized Composites, J Dent Res 59:800-808.[Abstract/Free Full Text]
- Delange, C.; Bausch, J.R.; and Davidson, C.L. (1980): The Curing Pattern of Photo-initiated Dental Composites, J Oral Rehabil 7:369-377.[CrossRef][Medline]
[Order article via Infotrieve]
- Eliades, G.C.; Vougiouklakis, G.J.; and Caputo, A.A.: Degree of Double Bond Conversion in Light-cured Composites, Dent Mater (in press).
- Ferracane, J.L. (1985): Correlation Between Hardness and Degree of Conversion During the Setting Reaction of Unfilled Dental Restorative Resins, Dent Mater 1:111-14.[CrossRef][Medline]
[Order article via Infotrieve]
- Ferracane, J.L.; Aday, P.; Matsumoto, H.; and Marker, V.A. (1986): Relationship Between Shade and Depth of Cure for Light-activated Dental Composite Resins, Dent Mater 2:80-84.[Medline]
[Order article via Infotrieve]
- Ferracane, J. and Greener, E.H. (1984): Fourier Transform Infrared Analysis of Degree of Polymerization in Unfilled Resins-Methods Comparison, J Dent Res 63:1093-1095.[Abstract/Free Full Text]
- Inoue, K. and Hayashi, I. (1982): Residual Monomer (Bis-GMA) of Composite Resins, J Oral Rehabil 9:493-497.[Medline]
[Order article via Infotrieve]
- Johnston, W.M.; Leung, R.L.; and Fan, P.L. (1985): A Mathematical Model for Post-irradiation Hardening of Photoactivated Composite Resins, Dent Mater 1:191-194.[Medline]
[Order article via Infotrieve]
- Leung, R.L.; Fan, P.L.; and Johnston, W. (1983): Post-irradiation Polymerization of Visible-light-activated Composite Resins, J Dent Res 62:363-365.[Abstract/Free Full Text]
- Leung, R.L.; Kahn, R.L.; and Fan, P.L. (1984): Comparison of Depth of Polymerization Evaluation Methods for Photo-activated Composite, J Dent Res 63:292, Abst. No. 1095.
- Li, Y.; Swartz, M.L.; Phillips, R.W.; Moore, B.K.; and Roberts, T.A. (1985): Effect of Filler Content and Size on Properties of Composites, J Dent Res 64:1396-1401.[Abstract/Free Full Text]
- Murray, G.A.; Yates, J.L.; and Newman, S.M. (1981): Ultraviolet Light and Ultraviolet Light-activated Composite Resins, J Prosthet Dent 46:167-170.[Medline]
[Order article via Infotrieve]
- Newman, S.M. and Murray, G.A. (1983): Visible Lights and Visible Light Activated Composite Resins, J Prosthet Dent 50:31-35.[Medline]
[Order article via Infotrieve]
- Ruyter, I.E. and Oysæd, H. (1982): Conversion in Different Depths of Ultraviolet and Visible Light-activated Composite Materials, Acta Odontol Scand 40:179-192.[CrossRef][Medline]
[Order article via Infotrieve]
- Skeeters, T.M.; Timmons, J.G.; and Mitchell, R.J. (1983): Curing Depth of Visible Light Cured Composite Resin, J Dent Res 62:219, Abst. No. 448 (AADR).
- Tirtha, R.; Fan, P.L.; Dennison, J.B.; and Powers, J.M. (1982): In vitro Depth of Cure of Photo-activated Composites, J Dent Res 61:1184-1187.[Abstract/Free Full Text]
Journal of Dental Research, Vol. 66, No. 3,
727-730 (1987)
DOI: 10.1177/00220345870660030401

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
Influence of Food Simulating Solutions on the Hardness of Composite Resins
Journal of Composite Materials,
January 1, 2008;
42(1):
69 - 75.
|
 |
|

|
 |

|
 |
 
P.L. FAN, R. M. SCHUMACHER, K. AZZOLIN, R. GEARY, and F. C. EICHMILLER
Curing-light intensity and depth of cure of resin-based composites tested according to international standards
J Am Dent Assoc,
April 1, 2002;
133(4):
429 - 434.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
J. MANHART, H. Y. CHEN, and R. HICKEL
The suitability of packable resin-based composites for posterior restorations
J Am Dent Assoc,
May 1, 2001;
132(5):
639 - 645.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
M. Kawaguchi, T. Fukushima, and K. Miyazaki
The Relationship Between Cure Depth and Transmission Coefficient of Visible-light-activated Resin Composites
Journal of Dental Research,
February 1, 1994;
73(2):
516 - 521.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
H. Suzuki, M. Taira, K. Wakasa, and M. Yamaki
Refractive-index-adjustable Fillers for Visible-light-cured Dental Resin Composites: Preparation of TiO 2-SiO2 Glass Powder by the Sol-gel Process
Journal of Dental Research,
May 1, 1991;
70(5):
883 - 888.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
F.A. Rueggeberg and R.G. Craig
Correlation of Parameters used to Estimate Monomer Conversion in a Light-cured Composite
Journal of Dental Research,
June 1, 1988;
67(6):
932 - 937.
[Abstract]
[PDF]
|
 |
|
|
|