A Histological Assessment of the Initial Healing Response Adjacent to Porous-surfaced, Titanium Alloy Dental Implants in Dogs
D.A. Deporter
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
P.A. Watson
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
R.M. Pilliar
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
A.H. Melcher
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
J. Winslow
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
T.P. Howley
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
P. Hansel
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
C. Maniatopoulos
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
A. Rodriguez
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
D. Abdulla
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
K. Parisien
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
D.C. Smith
MRC Program in Dental Implantology, Faculty of Dentistry, University of Toronto, 124 Edward Street, Toronto, Ontario, Canada M5G 1G6
We report here the results of a histological assessment of the initial healing response following implantation into the dog mandible of a porous-surfaced, titanium alloy endosseous dental implant. Two implants were placed in edentulous areas on each side of the mandible of each dog and covered with a full-thickness mucoperiosteal flap. The implant sites on one side of the mandible were allowed to heal for four weeks, while those on the other side were allowed to heal for eight weeks before the animals were killed. Histological specimens were obtained and assessed both qualitatively and by computer-assisted morphometry. All but one of the 24 implants were well-tolerated and healed with a variable ingrowth of bone into the porous-surface geometry. The histomorphometric measurements revealed that bone ingrowth had reached a plateau by four weeks of initial healing.
REFERENCES
- Armor, D.J. and Couch, A.S. (1972): Data-Text Primer. New York: The Free Press.
- Bobyn, J.D.; Pilliar, R.M.; Cameron, H.U.; and Weath-Erly, G.C. (1980): The Optimum Pore Size for the Fixation of Porous-surfaced Metal Implants by the Ingrowth of Bone, Clin Orthop Rel Res 150:263-270.[Medline]
[Order article via Infotrieve]
- Branemark, P.-I. (1983): Osseointegration and Its Experimental Background, J Prosthet Dent 50:399-410.[Medline]
[Order article via Infotrieve]
- Branemark, P.I.; Hansson, B.O.; and Adell, R. (1977): Osseointegrated Implants in the Treatment of the Edentulous Jaw. Experience from a 10 Year Period, Scand J Plast Reconstr Surg (Suppl) 16:1-132.[Medline]
[Order article via Infotrieve]
- Cook, S.D.; Klawitter, J.J.; and Weinstein, A.M. (1982): A Model for the Implant-Bone Interface Characteristics of Porous Dental Implants, J Dent Res 61:1006-1009.[Abstract/Free Full Text]
- Cook, S.D.; Weinstein, A.M.; Sander, T.A.; and Klawitter, J.J. (1982): Retention Characteristics of Porous Rooted Co-Cr-Mo Alloy Dental Implants, Biomater Med Dev Art Org 10: 123-146.
- Deporter, D.A.; Friedland, B.; Watson, P.A.; Pilliar, R.M.; Howley, T.P.; Abdulla, D.; Melcher, A.H.; and Smith, D.C. (1986): A Clinical and Radiographic Assessment of a Porous-surfaced, Titanium Alloy Dental Implant System in Dogs, J Dent Res 65:1071-1077.[Abstract/Free Full Text]
- Ducheyne, P.; Hench, L.L.; Kagan, A.; Martens, M.; Bursens, A.; and Mulier, J.C. (1980): Effect of Hydroxyapatite Impregnation on Skeletal Bonding of Porous Coated Implants, J Biomed Mater Res 14:225-237.[CrossRef][Medline]
[Order article via Infotrieve]
- Galante, J.; Rostoker, W.; Lueck, R.; and Ray, R. (1971): Sintered Fiber Metal Composites as a Basis for Attachment of Implants to Bone, J Bone Joint Surg 53A:101-114.[Abstract/Free Full Text]
- Glass, G.V. and Stanley, J.C. (1970): Statistical Methods in Education and Psychology. Englewood Cliffs, NJ: Prentice-Hall.
- Harris, W.H.; White, R.E., Jr.; McCarthy, J.C.; Walker, P.S.; and Weinberg, E.H. (1983): Bony Ingrowth Fixation of the Acetabular Component in Canine Hip Joint Arthroplasty, Clin Orthop 176:7-11.
- Karagianes, M.T.; Westerman, R.E.; Hamilton, A.I.; Adams, H.F.; and Wills, R.C. (1982): Investigation of Long-term Performance of Porous-Metal Dental Implants in Nonhuman Primates, J Oral Implantol 10:189-207.[Medline]
[Order article via Infotrieve]
- Karagianes, M.T.; Westerman, R.E.; Rasmussen, J.J.; and Codwell, A.M. (1976): Development and Evaluation of Porous Dental Implants in Miniature Swine, J Dent Res 55:85-93.[Abstract/Free Full Text]
- Peterson, L.J.; McKinney, R.V., Jr.; Pennel, B.M.; Klawitter, J.J.; and Weinstein, A.M. (1980): Clinical, Radiographic, and Histological Evaluation of Porous Rooted Cobalt-Chromium Alloy Dental Implants, J Dent Res 59:99-108.[Abstract/Free Full Text]
- Pilliar, R.M. (1983): Powder Metal-made Orthopedic Implants with Porous Surface for Fixation by Tissue Ingrowth, Clin Orthop Rel Res 176:42-51.
- Pilliar, R.M.; Cameron, H.U.; Welsh, R.P.; and Binning-Ton, A.G. (1981): Radiographic and Morphologic Studies of Load-bearing Porous-surfaced Structured Implants, Clin Orthop Rel Res 156:249-257.
- Solar, R.J. (1979): Corrosion Resistance of Titanium Surgical Implant Alloys: A Review. In: Corrosion and Degradation of Implant Materials, ASTM STP 684, Philadelphia: American Society for Testing and Materials, pp. 259-273.
- Spector, M.; Davis, R.J.; Lunceford, E.M.; and Harmon, S.L. (1983): Porous Polysulfone Coatings for Fixation of Femoral Stems by Bony Ingrowth, Clin Orthop 176:34.
- Weiss, M.B. and Rostoker, W. (1982): Development of a New Endosseous Dental Implant, Pt. II, Human Studies, J Prosthet Dent 47:633-645.
- Wie, H.; Solheim, T.; and Riise, P.A. (1975): Methyl Methacrylate Screw Implants-Radiographic, Histological and Fluorescence Microscopic Investigations in Dogs, J Oral Rehabil 2:225-233.[Medline]
[Order article via Infotrieve]
- Winer, B.J. (1971): Statistical Principles in Experimental Design, 2nd ed. New York: McGraw-Hill.
- Young, F.A.; Kresch, C.H.; and Spector, M. (1979a): Porous Titanium Tooth Roots: Clinical Evaluation, J Prosthet Dent 41:561-565.[Medline]
[Order article via Infotrieve]
- Young, F.A.; Spector, M.; and Kresch, C.H. (1979b): Porous Titanium Endosseous Dental Implants in Rhesus Monkeys: Micro-radiography and Histological Evaluation, J Biomed Mater Res 13:843-856.[Medline]
[Order article via Infotrieve]
Journal of Dental Research, Vol. 65, No. 8,
1064-1070 (1986)
DOI: 10.1177/00220345860650080501

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
C.M. Stanford, J.C. Keller, and M. Solursh
Bone Cell Expression on Titanium Surfaces is Altered by Sterilization Treatments
Journal of Dental Research,
May 1, 1994;
73(5):
1061 - 1071.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M.A. Listgarten, D. Buser, S.G. Steinemann, K. Donath, N.P. Lang, and H.P. Weber
Light and Transmission Electron Microscopy of the Intact Interfaces Between Non-submerged Titanium-coated Epoxy Resin Implants and Bone or Gingiva
Journal of Dental Research,
February 1, 1992;
71(2):
364 - 371.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
C. M. Stanford and J. C. Keller
The Concept of Osseointegration and Bone Matrix Expression
Critical Reviews in Oral Biology & Medicine,
January 1, 1991;
2(1):
83 - 101.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
D.A. Deporter, P.A. Watson, R.M. Pilliar, M.L. Chipmani, and N. Valiquette
A Histological Comparison in the Dog of Porous-coated vs. Threaded Dental Implants
Journal of Dental Research,
May 1, 1990;
69(5):
1138 - 1145.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D.A. Deporter, P.A. Watson, R.M. Pilliar, T.P. Howley, and J. Winslow
A Histological Evaluation of a Functional Endosseous, Porous-surfaced, Titanium Alloy Dental Implant System in the Dog
Journal of Dental Research,
September 1, 1988;
67(9):
1190 - 1195.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D.A. Deporter, B. Friedland, P.A. Watson, R.M. Pilliar, T.P. Howley, D. Abdulla, A.H. Melcher, and D.C. Smith
A Clinical and Radiographic Assessment of a Porous-surfaced, Titanium Alloy Dental Implant System in Dogs
Journal of Dental Research,
August 1, 1986;
65(8):
1071 - 1077.
[Abstract]
[PDF]
|
 |
|
|
|