X-ray Diffraction Analysis of 2 (Sn-Hg) Phase in High Copper Amalgams of Varying Mercury Content
Manohar L. Malhotra
School of Dentistry, The University of Michigan, Ann Arbor, Michigan 48109
Kamal Asgar
School of Dentistry, The University of Michigan, Ann Arbor, Michigan 48109
Microstructures of high copper commercial amalgams containing varying amounts of mercury, ranging from 20% above to 25% below recommended values, were primarily investigated by x-ray diffraction. Mechanisms relating to the absence or presence of 2 (Sn-Hg) phase in these amalgams were discussed in relation to the presence of copper and tin elements in their original alloys. The optimum mercury concentration in some amalgams was determined in order to keep them free of the 2 (Sn-Hg) phase.
REFERENCES
- Council on Dental Materials and Devices, American Dental Association: List of Certified Dental Materials and Devices Revised to Jan. 1, 1977,JADA 94:135, 1977.
- Council on Dental Materials and Devices, American Dental Association: Supplement of the List of Certified Dental Materials and Devices, JADA 95:131, 1977.
- Council on Dental Materials and Devices, American Dental Association: Certified Alloys for Dental Amalgam, JADA 96: 126, 1978.
- Malhotra, M.L. and Asgar, K.: Physical Properties of Dental Silver-Tin Amalgams with High and Low Copper Contents, JADA 96:444, 1978.
- Malhotra, M.L. and Asgar, K.: Microstructure of Dental Amalgams Containing High and Low Copper Contents, J Dent Res 56:1481-1487, 1977.[Abstract/Free Full Text]
- Marek M. and Hochman, R.F.: Corrosion Properties of a Low Silver and High Copper Dental Amalgam, IADR Progr & Abst 55: No. 282, 1976.
- Moffa, J.P. and Jenkins, W.A.: Two Year Clinical Evaluation of a Dispersed Phase and a Single Phase Amalgam, IADR Progr & Abst 56: No. 114, 1977.
- Jensen, S.J.: Phase Content of a High Copper Dental Silver Amalgam, Scand J Dent Res 85:297, 1977.[Medline]
[Order article via Infotrieve]
- Mahler, D.B. and Adey, J.D.: Characteristics of a High Copper Amalgam, IADR Progr & Abst 56: No. 145, 1977.
- Mahler, D.B.: Behavior of Three High-Cu Amalgams, J Biomed Mater Res 13:693, 1979.[CrossRef][Medline]
[Order article via Infotrieve]
Journal of Dental Research, Vol. 60, No. 2,
149-153 (1981)
DOI: 10.1177/00220345810600021001

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
R.J. Mitchell and T. Okabe
Setting Reactions in Dental Amalgam Part 1. Phases and Microstructures Between One Hour and One Week
Critical Reviews in Oral Biology & Medicine,
January 1, 1996;
7(1):
12 - 22.
[Abstract]
[Full Text]
[PDF]
|
 |
|
|
|