|
Sign In to gain access to subscriptions and/or personal tools.
|
A 30-month Clinical Evaluation of the Influence of Finishing and Size of Restoration on the Margin Performance of Five Amalgam Alloys
R.F. Birtcil, Jr
Department of Restorative Dentistry, University of California School of Dentistry, San Francisco, California 94143
R.B. Pelzner
Department of Operative Dentistry, University of California School of Dentistry, San Francisco, California 94143
M.M. Stark
Departmenet of Operative Dentistry and Oral Biology, University of California School of Dentistry, San Francisco, California 94143
The influence of finishing and size of the restoration on the margin performance of 286 Class II restorations using five amalgam alloys (Aristaloy, Dispersalloy, Oraloy, Sybraloy, and Tytin) was evaluated at 30 mo. When size of the restoration was considered, Dispersalloy displayed the best margin performance. Oraloy, Sybraloy, and Tytin were inferior to Dispersalloy and were grouped together. Aristaloy was inferior to all other alloys in the study. When the aspect of finishing was considered, Dispersalloy and Sybraloy evidenced excellent margin performance when unfinished. Aristaloy showed the worst margin performance of all the alloys in the study when unfinished, but showed remarkable improvement in margin performance when finished.
REFERENCES
- Eames, W.B. and MacNamara, J.F.: Eight High-copper Amalgam Alloys and Six Conventional Alloys Compared, Oper Dent 1(3):98-107,1976.[Medline]
[Order article via Infotrieve]
- Eames, W.B.; MacNamara, J.F.; and Palmertree, C.O.: High-copper Amalgam Alloys - An Update, J Indiana Dent Assoc 55(6):27-31, 1976.[Medline]
[Order article via Infotrieve]
- Malhotra, M.L. and Asgar, K.: Physical Properties of Dental Silver-tin Amalgams with High and Low Copper Contents, JADA 96(3):444-450, 1978.
- Mahler, D.B.; Terkla, L.G.; and van Eysden, J.: Marginal Fracture of Amalgam Restorations, J Dent Res 5(4):823-827, 1973.
- Osborne, J.W.; Swartz, M.L.; Gale, E.N.; and Phillips, R.W.: Clinical Performance of Ten Amalgam Alloys, AADR Progr & Abst 56:No. 250, 1977.
- Duperon, D.F.; Neville, M.D.; and Kasloff, Z.: Clinical Evaluation of Corrosion Resistance of Conventional Alloy, Spherical-particle Alloy, and Dispersion Phase Alloy, J Prosthet Dent 25(6):650-656, 1971.[CrossRef][Medline]
[Order article via Infotrieve]
- Osborne, J.W.; Phillips, R.W.; Gale, E.N.; and Binon, P.P.: Three-year Clinical Comparison of Three Amalgam Alloy Types Emphasizing an Appraisal of the Evaluation Methods Used, JADA 93(4):784-789, 1976.
- Osborne, J.W.; Gale, E.N.; Chew, C.C.; Rhodes, B.F.; and Phillips, R.W.: Clinical Performance and Physical Properties of Twelve Amalgam Alloys, J Dent Res 57: 983-988,1978.[Abstract/Free Full Text]
- Osborne, J.W. and Gale, E.N.: Failure Rate of Margins of Amalgams with a High Content of Copper, Oper Dent 4(1):2-8, 1979.[Medline]
[Order article via Infotrieve]
- Osborne, J.W.; Gale, E.N.; Cock, D.C.; and Phillips, R.W.: Clinical Assessment of Marginal Breakdown Rate of Nine High-copper Content Amalgams, IADR Progr & Abst 57:No. 26, 1978.
- Rupp, N.W.: Dental Amalgam, a Plea for Clinical Research, J Am Acad of Gold Foil Operators 18(1):29-31, 1975.
- Jorgensen, K.D.: The Strength of Corroded Amalgam, Acta Odont Scand 30(3): 33-38, 1972.[CrossRef][Medline]
[Order article via Infotrieve]
- Jorgensen, K.D.: The Mechanisms of Marginal Fracture of Amalgam Fillings, Acta Odont Scand 23(8):347-389, 1965.[CrossRef][Medline]
[Order article via Infotrieve]
- Mahler, D.B.; Terkla, L.G.; and Reis-Bick, M.H.: Marginal Fracture vs. Mechanical Properties of Amalgam, J Dent Res 49(Suppl): 1452-1457, 1970.[Abstract/Free Full Text]
- Osborne, J.W.; Phillips, R.W.; Norman, R.D.; and Swartz, M.L.: Static Creep of Certain Amalgam Alloys, JADA 89(3):620-622, 1974.
- Mahler, D.B.; Adey, J.D.; and van Eysden, J.: Quantitative Microprobe Techniques, J Dent Res 51(3):789, 1972.[Abstract/Free Full Text]
- Jordan, R.E.; Suzuki, M.; and Mills, A.R.: Marginal Integrity of Amalgam Alloys in Relation to Creep: A Preliminary Report, J Prosthet Dent 40(3):299-303, 1978.[CrossRef][Medline]
[Order article via Infotrieve]
- Mahler, D.B. and Marantz, R.: The Effect of the Operator on the Clinical Performance of Amalgam, JADA 99(1):38-41,1979.
- Osborne, J.W.; Phillips, R.W.; Gale, E.N.; and Norman, R.D.: Clinical Assessment of the Marginal Breakdown of Conventional Alloys Adjacent to a Dispersion Alloy, J Dent Res 55(6):1140, 1976.[Free Full Text]
- Letzel, H.; Aardening, C.J.M.W.; Fick, J.M.; van Leusen, J.; and Vrijhoef, M.M.A.: Tarnish, Corrosion, Marginal Fracture , and Creep of Amalgam Restorations: A Two-year Clinical Study, Oper Dent 3(3): 82-92, 1978.
- Young, F.A. and Johnson, L.B.: Strength of the Tin-Mercury Phase in Dental Amalgam, J Dent Res 46(2):457, 1967.[Free Full Text]
- Holland, G.A. and Asgar, K.: Some Effects on the Phases of Amalgam Induced by Corrosion, J Dent Res 53(%):1245-1254,1974.
- Zuwaylif, F.H.: General Applied Statistics, 2nd ed., Reading, MA: Addison-Wesley Publishing Co., 1973, p. 298.
- Arley, N. and Buch, K.R.: Introduction to the Theory of Probability and Statistics, 2nd ed., New York: John Wiley & Sons, Inc., 1965, pp. 170,208.
Journal of Dental Research, Vol. 60, No. 12,
1949-1956 (1981)
DOI: 10.1177/00220345810600120501

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
K.-J.M. Soderholm, M.J. Tyas, and A. Jokstad
Determinants of Quality in Operative Dentistry
Critical Reviews in Oral Biology & Medicine,
January 1, 1998;
9(4):
464 - 479.
[Abstract]
[Full Text]
[PDF]
|
 |
|

|
 |

|
 |
 
R.J. Smales and D.C. Gerke
A High-copper Amalgam Evaluated after Three Years in City and Country Practices
Journal of Dental Research,
November 1, 1986;
65(11):
1353 - 1355.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
D.B. Mahler, J.H. Engle, and R.W. Bryant
Standardizing Evaluations of the Clinical Marginal Fracture of Amalgam
Journal of Dental Research,
August 1, 1986;
65(8):
1108 - 1111.
[Abstract]
[PDF]
|
 |
|
|
|