Advanced Search

Journal Navigation

Journal Home

Subscriptions

Archive

Contact Us

Table of Contents

Click here to sign up for SAGE Journal Email Alerts today!

Sign In to gain access to subscriptions and/or personal tools.
Journal of Dental Research
This Article
Right arrow Full Text (PDF)
Right arrow References
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Saved Citations
Right arrow Download to citation manager
Right arrowRequest Permissions
Right arrow Request Reprints
Right arrow Add to My Marked Citations
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Right arrow Citing Articles via Scopus
Google Scholar
Right arrow Articles by Della Bona, A.
Right arrow Articles by van Noort, R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Della Bona, A.
Right arrow Articles by van Noort, R.
Right arrowPubmed/NCBI databases
*Compound via MeSH
*Substance via MeSH
Hazardous Substances DB
*HYDROFLUORIC ACID
Social Bookmarking
 Add to CiteULike   Add to Complore   Add to Connotea   Add to Del.icio.us   Add to Digg   Add to Reddit   Add to Technorati   Add to Twitter  
What's this?

Shear vs. Tensile Bond Strength of Resin Composite Bonded to Ceramic

A. Della Bona

Department of Restorative Dentistry, University of Sheffield, S10 2TA, Sheffield, United Kingdom

R. van Noort

Department of Restorative Dentistry, University of Sheffield, S10 2TA, Sheffield, United Kingdom

Since the mode of failure of resin composites bonded to ceramics has frequently been reported to be cohesive fracture of either ceramic or resin composite rather than separation at the adhesive interface, this study was designed to question the validity of shear bond strength tests. The reasons for such a failure mode are identified and an alternative tensile bond strength test evaluated. Three configurations (A, conventional; B, reversed; and C, all composite) of the cylinder-on-disc design were produced for shear bond strength testing. Two-dimensional finite element stress analysis (FEA) was carried out to determine qualitatively the stress distribution for the three configurations. A tensile bond strength test was designed and used to evaluate two ceramic repair systems, one using hydrofluoric acid (HF) and the other acidulated phosphate fluoride (APF). Results from the shear bond strength tests and FEA showed that this particular test has as its inherent feature the measurement of the strength of the base material rather than the strength of the adhesive interface. In the tensile test, failure invariably occurred in the adhesive layer, with HF and APF showing a similar ability to improve the bond of resin composite to ceramic. It is concluded that the tensile bond strength test is more appropriate for evaluating the adhesive capabilities of resin composites to ceramics.

Key Words: tensile • shear • bond strength • finite element

Journal of Dental Research, Vol. 74, No. 9, 1591-1596 (1995)
DOI: 10.1177/00220345950740091401


Add to CiteULike CiteULike   Add to Complore Complore   Add to Connotea Connotea   Add to Del.icio.us Del.icio.us   Add to Digg Digg   Add to Reddit Reddit   Add to Technorati Technorati   Add to Twitter Twitter    What's this?


This article has been cited by other articles:


Home page
Eur J OrthodHome page
H. Bulut, A. D. Kaya, and M. Turkun
Tensile bond strength of brackets after antioxidant treatment on bleached teeth
Eur J Orthod, October 1, 2005; 27(5): 466 - 471.
[Abstract] [Full Text] [PDF]


Home page
Journal of the American Dental AssociationHome page
C. SHEN, E. MONDRAGON, V. V. GORDAN, and I. A. MJOR
The effect of mechanical undercuts on the strength of composite repair
J Am Dent Assoc, October 1, 2004; 135(10): 1406 - 1412.