| Sign In to gain access to subscriptions and/or personal tools. |
Interferometric Measurements of Cusp Deformation of Teeth Restored with CompositesDepartment of Conservative Dentistry, College of Dentistry, University of Mosul, Mosul, Iraq
Department of Operative Dentistry
College of Dentistry, and Department of Biomedical Engineering, The University of Iowa, Iowa City, Iowa 52242 A Michelson interferometry apparatus was used for measurement of the displacement of the buccal cusps of premolars after restoration of MOD preparations with composites. The effects of composite type, cavity size, and hydration conditions were examined. Interferometry permitted real-time measurement of cusp movement as it occurred. Contraction occurred very rapidly, about 1/3 of the 60-minute amount within the two-minute period of exposure to the curing light. Cusp movement was smooth rather than interrupted, indicating lack of microfracturing at deformations of 11-46 µm. Contraction, 0.94% for Heliomolar and 1.2% for P-50, was similar to the linear polymerization shrinkage of the resins. Less cusp movement occurred in small cavities than in large cavities. Hydrated teeth had less cusp movement than dehydrated teeth.
Journal of Dental Research, Vol. 72, No. 11,
1532-1536 (1993) This article has been cited by other articles:
|
|
|||||||||||||||||||||||||||