Sign In to gain access to subscriptions and/or personal tools.
|
Assessment of the Reliability of Radiographic Diagnosis in a Clinical Caries Trial
Paul F. De Paola
Forsyth Dental Center and Boston University Computing Center, Boston, Massachusetts 02115, USA
John Alman
Forsyth Dental Center and Boston University Computing Center, Boston, Massachusetts 02115, USA
A method of repeated assessment of radiographic study material was used in an attempt to develop indices of consistency and reliability. The interpretation of the coefficient of reliability was complicated by the large intersubject variability relative to examiner error. Of the various indices generated, the F tests for replications and for treatment by replication interaction are suggested as useful immediately.
Journal of Dental Research, Vol. 51, No. 5,
1431-1437 (1972)
DOI: 10.1177/00220345720510053001

CiteULike Complore Connotea Del.icio.us Digg Reddit Technorati Twitter What's this?
This article has been cited by other articles:

|
 |

|
 |
 
R.W. Valachovic, C.W. Douglass, C.S. Berkey, B.J. McNeil, and H.H. Chauncey
Examiner Reliability in Dental Radiography
Journal of Dental Research,
March 1, 1986;
65(3):
432 - 436.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
N.B. Pitts and C.E. Renson
Reproducibility of Computer-aided Image-analysis-derived Estimates of the Depth and Area of Radiolucencies in Approximal Enamel
Journal of Dental Research,
October 1, 1985;
64(10):
1221 - 1224.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
J. L. Fleiss, M. J. Slakter, S. L. Fischman, M. H. Park, and N. W. Chilton
Inter-examiner Reliability in Caries Trials
Journal of Dental Research,
February 1, 1979;
58(2):
604 - 609.
[Abstract]
[PDF]
|
 |
|

|
 |

|
 |
 
M. J. Slakter, D. B. Juliano, and S. L. Fischman
Estimating Examiner Consistency with DMFS Measures
Journal of Dental Research,
November 1, 1976;
55(6):
930 - 934.
[Abstract]
[PDF]
|
 |
|
|
|